Condensing boiler + sanitary upgrade — Sint-Amandsberg
Old wall-hung boiler swapped for a high-efficiency condensing unit with separate cylinder, plus tweaks to the sanitary loop.
- Location
- Sint-AmandsbergGhent area
- Year
- 2025
- Duration
- 1 week
- Services
- HeatingPlumbing

Portfolio
How it went
A family home in Sint-Amandsberg with an atmospheric boiler from 1998 on its last legs. We installed a 25 kW Vaillant condensing boiler with a 150 L external stainless cylinder.
The flue was rebuilt in twin-wall through the existing chimney — concentric Ø 80/125. Heating water was fully drained, flushed and treated with inhibitor; a magnetic filter was added on the return.
Sanitary: old copper lines on the bathroom floor were leaking. Swapped for PER with a fresh manifold on the landing. Hot-water runs were insulated to cut losses.
One working week from teardown to commissioning, including gas-tightness test and certificate for the inspection.